OEM Service Manual: York YK Centrifugal Chiller Service Manual (Form 160.60-S1). Johnson Controls Technical Literature.
30 codes
Fault CodeAlarm DescriptionSeverityProbable CausesAction
E1 Compressor motor over-temperature Warning Motor bearing failure View Details →
E2 Guide vane position fault Warning Guide vane actuator motor failure View Details →
E3 VSD communication fault Warning VSD communication cable damaged View Details →
E4 VSD over-temperature Warning VSD heatsink temperature high View Details →
E5 Surge detection alarm Warning Operating near surge line View Details →
E6 Oil pressure low Critical Oil pump failure View Details →
E7 Oil temperature high Warning Oil cooler fouled View Details →
E8 Condenser water flow fault Warning Condenser pump stopped View Details →
E9 Evaporator water flow fault Warning Chilled water pump stopped View Details →
EA High condenser pressure Warning Condenser water temp too high View Details →
EB Low evaporator temperature Warning Low refrigerant charge View Details →
EC Motor current overload Warning Bearing failure View Details →
ED Phase loss or reversal Critical Missing phase View Details →
EE BAS communication fault Warning Network cable fault View Details →
EF Oil leak detection Warning Oil leak detected in system View Details →
F1 Compressor vibration alarm Warning Mounting bolts loose View Details →
E10 Compressor motor bearing temperature high Warning Bearing lubrication inadequate View Details →
E11 Low refrigerant charge detected Warning Refrigerant leak in system View Details →
E12 High oil discharge temperature Warning Oil cooler inefficiency View Details →
E13 Variable geometry inlet fault Warning Inlet guide vane actuator failure View Details →
E14 Pumpdown sequence fault Warning Pumpdown solenoid valve not closing View Details →
E15 Compressor surge detection Warning Operating near surge line View Details →
E16 Oil leak detection Warning Oil leak detected View Details →
E17 VSD speed feedback fault Warning Speed feedback sensor failure View Details →
E18 VSD motor overload Critical Compressor motor excessive current View Details →
E19 VSD DC bus overvoltage Warning Regenerative energy View Details →
E20 VSD DC bus undervoltage Warning Input voltage sag View Details →
E21 VSD output phase loss Critical Output terminal loose View Details →
E22 VSD ground fault Warning Ground fault on output View Details →
E23 VSD communication timeout Warning Communication timeout View Details →
[PDF] Quick Reference Card Download printable PDF for YK fault codes Download PDF
Disclaimer: All York YK fault code data is for reference only. Do not use this information to replace certified professional HVAC technician judgment. Always refer to original OEM official service manual.