OEM Service Manual: McQuay MCS Modular Chiller Service Manual. Available through Daikin Applied technical support.
30 codes
Fault CodeAlarm DescriptionSeverityProbable CausesAction
E01 Module 1 compressor high pressure Critical Module 1 condenser fouled View Details →
E02 Module 1 compressor low pressure Warning Low refrigerant in module 1 View Details →
E03 Module 2 compressor fault Warning Module 2 compressor overload View Details →
E04 Module 3 compressor fault Warning Module 3 compressor overload View Details →
E05 Module communication fault Warning Inter-module communication cable damaged View Details →
E06 Common evaporator water flow fault Warning Chilled water pump stopped View Details →
E07 Module isolation valve fault Warning Isolation valve motor failure View Details →
E08 Capacity control fault Warning Capacity staging logic error View Details →
E09 Sensor fault Warning Sensor element failure View Details →
E10 Phase fault Warning Phase loss View Details →
E11 Oil pressure fault Warning Oil pump wear View Details →
E12 Power supply fault Warning Voltage outside spec View Details →
E13 Freeze protection Critical Evaporator water temp near freezing View Details →
E14 Expansion valve fault Warning Valve motor failure View Details →
E15 Fan motor fault Warning Motor winding failure View Details →
E16 Condenser water temperature high Warning Cooling tower issue View Details →
E17 Condenser fan 2 fault Warning Fan 2 motor failure View Details →
E18 Compressor vibration alarm Warning Mounting loose View Details →
E19 Pumpdown failure Warning Solenoid not closing View Details →
E20 Compressor surge alarm Warning Near surge line View Details →
E21 High bearing temperature Warning Lubrication inadequate View Details →
E22 Low subcooling alarm Warning Charge low View Details →
E23 High superheat alarm Warning Valve starving View Details →
E24 Compressor start inhibit Warning Safety interlock preventing start View Details →
E25 Evaporator approach temperature high Warning Fouled tubes View Details →
E26 Condenser approach temperature high Warning Fouled condenser View Details →
E27 Energy efficiency alarm Warning Below expected efficiency View Details →
E28 Compressor runtime exceeded Warning Exceeded max runtime View Details →
E29 Refrigerant level alarm Warning Level sensor low View Details →
E30 Cooling tower water fault Warning Tower fan not operating View Details →
[PDF] Quick Reference Card Download printable PDF for MCS fault codes Download PDF
Disclaimer: All McQuay MCS fault code data is for reference only. Do not use this information to replace certified professional HVAC technician judgment. Always refer to original OEM official service manual.