OEM Service Manual: Multistack ASP Air-Cooled Modular Chiller Service Manual. Available through Multistack International technical support.
30 codes
| Fault Code | Alarm Description | Severity | Probable Causes | Action |
|---|---|---|---|---|
| E01 | Module 1 compressor high pressure | Critical | Condenser coil fouled | View Details → |
| E02 | Module 1 compressor low pressure | Warning | Low refrigerant charge | View Details → |
| E03 | Module 1 compressor motor overload | Critical | Motor bearing failure | View Details → |
| E04 | Module 2 compressor fault | Warning | Module 2 compressor overload | View Details → |
| E05 | Condenser fan fault | Warning | Fan motor failure | View Details → |
| E06 | Module communication fault | Warning | Inter-module cable damaged | View Details → |
| E07 | Evaporator water flow fault | Warning | Pump stopped | View Details → |
| E08 | Freeze protection | Critical | Evaporator temp near freezing | View Details → |
| E09 | Sensor fault | Warning | Sensor element failure | View Details → |
| E10 | Phase fault | Warning | Phase loss | View Details → |
| E11 | Overcurrent protection | Critical | Motor overload | View Details → |
| E12 | Oil level low | Critical | Oil leak | View Details → |
| E13 | Module isolation valve fault | Warning | Valve motor failure | View Details → |
| E14 | Power supply fault | Warning | Voltage outside spec | View Details → |
| E15 | Capacity control fault | Warning | Staging logic error | View Details → |
| E16 | Communication fault | Warning | Network cable fault | View Details → |
| E17 | Condenser fan 2 fault | Warning | Fan 2 motor failure | View Details → |
| E18 | Compressor vibration alarm | Warning | Mounting loose | View Details → |
| E19 | Pumpdown failure | Warning | Solenoid not closing | View Details → |
| E20 | Compressor surge alarm | Warning | Near surge line | View Details → |
| E21 | High bearing temperature | Warning | Lubrication inadequate | View Details → |
| E22 | Low subcooling alarm | Warning | Charge low | View Details → |
| E23 | High superheat alarm | Warning | Valve starving | View Details → |
| E24 | Compressor start inhibit | Warning | Safety interlock | View Details → |
| E25 | Evaporator approach temperature high | Warning | Fouled tubes | View Details → |
| E26 | Condenser approach temperature high | Warning | Fouled condenser | View Details → |
| E27 | Energy efficiency alarm | Warning | Below expected efficiency | View Details → |
| E28 | Compressor runtime exceeded | Warning | Exceeded max runtime | View Details → |
| E29 | Refrigerant level alarm | Warning | Level sensor low | View Details → |
| E30 | High ambient temperature alarm | Warning | Ambient exceeds design limit | View Details → |