OEM Service Manual: Lennox LCA Air-Cooled Chiller Service Manual. Available through Lennox Commercial technical support.
30 codes
Fault CodeAlarm DescriptionSeverityProbable CausesAction
E01 High pressure alarm Critical Condenser coil fouled View Details →
E02 Low pressure alarm Warning Low refrigerant charge View Details →
E03 Compressor overload Warning Motor bearing failure View Details →
E04 Discharge temperature high Warning High compression ratio View Details →
E05 Evaporator water flow fault Warning Pump stopped View Details →
E06 Sensor fault Warning Sensor element failure View Details →
E07 Freeze protection Critical Evaporator temp near freezing View Details →
E08 Communication fault Warning Network cable fault View Details →
E09 Phase fault Warning Phase loss View Details →
E10 Overcurrent protection Critical Motor overload View Details →
E11 Oil pressure low Critical Oil pump wear View Details →
E12 Oil level low Critical Oil leak View Details →
E13 Expansion valve fault Warning Valve motor failure View Details →
E14 Power supply fault Warning Voltage outside spec View Details →
E15 Fan motor fault Warning Motor winding failure View Details →
E16 Compressor 2 fault Warning Compressor 2 overload View Details →
E17 Condenser fan 2 fault Warning Fan 2 motor failure View Details →
E18 Compressor vibration alarm Warning Mounting loose View Details →
E19 Pumpdown failure Warning Solenoid not closing View Details →
E20 Compressor surge alarm Warning Near surge line View Details →
E21 High bearing temperature Warning Lubrication inadequate View Details →
E22 Low subcooling alarm Warning Charge low View Details →
E23 High superheat alarm Warning Valve starving View Details →
E24 Compressor start inhibit Warning Safety interlock View Details →
E25 Evaporator approach temperature high Warning Fouled tubes View Details →
E26 Condenser approach temperature high Warning Fouled condenser View Details →
E27 Chiller staging error Warning Staging logic error View Details →
E28 Energy efficiency alarm Warning Below expected efficiency View Details →
E29 Compressor runtime exceeded Warning Exceeded max runtime View Details →
E30 Refrigerant level alarm Warning Level sensor low View Details →
[PDF] Quick Reference Card Download printable PDF for LCA fault codes Download PDF
Disclaimer: All Lennox LCA fault code data is for reference only. Do not use this information to replace certified professional HVAC technician judgment. Always refer to original OEM official service manual.