McQuay PFS Fault Code E31

E31
High ambient temperature alarm
Warning
SAFETY WARNING: Commercial chillers contain high-pressure refrigerants and high-voltage electrical components (208V-4160V). Only EPA Section 608 certified technicians should perform diagnostic work. Always follow lockout/tagout procedures and wear appropriate PPE. Do not attempt repairs without proper training and equipment.
AI Summary

McQuay PFS Fault Code E31 is a warning alarm indicating: High ambient temperature alarm. The most common causes include Ambient exceeds design limit. Estimated repair time: 1-2 hours. This alarm requires immediate attention by a certified HVAC technician.

Alarm Description

High ambient temperature alarm

Brand: McQuay  |  Model: PFS (Air-Cooled Scroll Chiller)  |  Code: E31  |  Severity: Warning

Observable Symptoms

  • Controller displays alarm code and description
  • Chiller may be locked out or running in degraded mode
  • Alarm indicator light is illuminated on control panel

What to Check First

Before diving into detailed diagnostics, start with this quick first check:

Quick Start: Verify ambient temp

Probable Causes

  • Ambient exceeds design limit
  • Condenser capacity insufficient at high ambient
  • Low ambient kit fault

Recommended Inspection Steps

  1. Verify ambient temp
  2. Check condenser capacity
  3. Verify low ambient kit
  4. Reduce load if needed

Required Tools & Equipment

  • Infrared thermometer or calibrated temperature probe
  • Safety PPE (gloves, safety glasses, face shield)

Estimated Repair Time

1-2 hours

When to Call a Professional

  • If the fault persists after completing all recommended inspection steps
  • If you observe unusual noises, vibrations, or oil leaks from the compressor
  • If refrigerant charge levels are outside OEM specifications and EPA-certified recovery is needed
  • If electrical measurements show voltage imbalance greater than 2% between phases
  • If the fault recurs immediately after reset, indicating an unresolved safety condition
  • Contact an authorized McQuay service representative for warranty-covered repairs

Related Fault Codes

Other McQuay PFS codes that may be related:

OEM Service Manual Reference

OEM Reference: McQuay PFS Air-Cooled Scroll Chiller Service Manual. Available through Daikin Applied (formerly McQuay) technical support.

Frequently Asked Questions

What does McQuay PFS fault code E31 mean?

Fault code E31 on a McQuay PFS chiller indicates: High ambient temperature alarm. This is a warning alarm that requires diagnostic attention.

What causes McQuay PFS alarm code E31?

Common causes include: Ambient exceeds design limit; Condenser capacity insufficient at high ambient; Low ambient kit fault

How do I fix McQuay PFS error code E31?

Follow the recommended inspection steps below. Start with the quick check, then proceed through each step. If the fault persists after all steps, contact an authorized McQuay service representative.

Disclaimer: All lookup data is for reference only. Do not use this information to replace certified professional HVAC technician judgment. Always refer to original OEM official service manual for McQuay PFS service procedures.