McQuay PFS Fault Code E17

E17
Compressor 2 fault
Warning
SAFETY WARNING: Commercial chillers contain high-pressure refrigerants and high-voltage electrical components (208V-4160V). Only EPA Section 608 certified technicians should perform diagnostic work. Always follow lockout/tagout procedures and wear appropriate PPE. Do not attempt repairs without proper training and equipment.
AI Summary

McQuay PFS Fault Code E17 is a warning alarm indicating: Compressor 2 fault. The most common causes include Compressor 2 motor overload. Estimated repair time: 45-90 minutes. This alarm requires immediate attention by a certified HVAC technician.

Alarm Description

Compressor 2 fault

Brand: McQuay  |  Model: PFS (Air-Cooled Scroll Chiller)  |  Code: E17  |  Severity: Warning

Observable Symptoms

  • Controller displays alarm code and description
  • Chiller may be locked out or running in degraded mode
  • Alarm indicator light is illuminated on control panel

What to Check First

Before diving into detailed diagnostics, start with this quick first check:

Quick Start: Measure compressor 2 motor current

Probable Causes

  • Compressor 2 motor overload
  • Compressor 2 mechanical fault
  • Compressor 2 contactor fault

Recommended Inspection Steps

  1. Measure compressor 2 motor current
  2. Check compressor 2 contactor
  3. Inspect compressor 2 mechanically

Required Tools & Equipment

  • Clamp-on ammeter
  • Digital multimeter
  • Safety PPE (gloves, safety glasses, face shield)

Estimated Repair Time

45-90 minutes

When to Call a Professional

  • If the fault persists after completing all recommended inspection steps
  • If you observe unusual noises, vibrations, or oil leaks from the compressor
  • If refrigerant charge levels are outside OEM specifications and EPA-certified recovery is needed
  • If electrical measurements show voltage imbalance greater than 2% between phases
  • If the fault recurs immediately after reset, indicating an unresolved safety condition
  • Contact an authorized McQuay service representative for warranty-covered repairs

Related Fault Codes

Other McQuay PFS codes that may be related:

OEM Service Manual Reference

OEM Reference: McQuay PFS Air-Cooled Scroll Chiller Service Manual. Available through Daikin Applied (formerly McQuay) technical support.

Frequently Asked Questions

What does McQuay PFS fault code E17 mean?

Fault code E17 on a McQuay PFS chiller indicates: Compressor 2 fault. This is a warning alarm that requires diagnostic attention.

What causes McQuay PFS alarm code E17?

Common causes include: Compressor 2 motor overload; Compressor 2 mechanical fault; Compressor 2 contactor fault

How do I fix McQuay PFS error code E17?

Follow the recommended inspection steps below. Start with the quick check, then proceed through each step. If the fault persists after all steps, contact an authorized McQuay service representative.

Disclaimer: All lookup data is for reference only. Do not use this information to replace certified professional HVAC technician judgment. Always refer to original OEM official service manual for McQuay PFS service procedures.