Daikin EWAD Fault Code L1

L1
Inverter PCB temperature sensor fault
Warning
SAFETY WARNING: Commercial chillers contain high-pressure refrigerants and high-voltage electrical components (208V-4160V). Only EPA Section 608 certified technicians should perform diagnostic work. Always follow lockout/tagout procedures and wear appropriate PPE. Do not attempt repairs without proper training and equipment.
AI Summary

Daikin EWAD Fault Code L1 is a warning alarm indicating: Inverter PCB temperature sensor fault. The most common causes include Inverter board temperature sensor failure. Estimated repair time: 30-60 minutes (requires sensor replacement and calibration verification). This alarm requires immediate attention by a certified HVAC technician.

Alarm Description

Inverter PCB temperature sensor fault

Brand: Daikin  |  Model: EWAD (Screw Compressor Chiller)  |  Code: L1  |  Severity: Warning

Observable Symptoms

  • Temperature reading on controller display shows abnormal value or dashes
  • Chiller may not start or cycles erratically due to incorrect temperature input

What to Check First

Before diving into detailed diagnostics, start with this quick first check:

Quick Start: Check inverter board temperature sensor

Probable Causes

  • Inverter board temperature sensor failure
  • Sensor wiring damaged
  • Board overheating condition

Recommended Inspection Steps

  1. Check inverter board temperature sensor
  2. Verify board cooling fan operation
  3. Replace sensor if faulty
  4. Improve enclosure cooling

Required Tools & Equipment

  • Infrared thermometer or calibrated temperature probe
  • Safety PPE (gloves, safety glasses, face shield)
  • Wire tracing and continuity tester

Estimated Repair Time

30-60 minutes (requires sensor replacement and calibration verification)

When to Call a Professional

  • If the fault persists after completing all recommended inspection steps
  • If you observe unusual noises, vibrations, or oil leaks from the compressor
  • If refrigerant charge levels are outside OEM specifications and EPA-certified recovery is needed
  • If electrical measurements show voltage imbalance greater than 2% between phases
  • If the fault recurs immediately after reset, indicating an unresolved safety condition
  • Contact an authorized Daikin service representative for warranty-covered repairs

Related Fault Codes

Other Daikin EWAD codes that may be related:

OEM Service Manual Reference

OEM Reference: Daikin EWAD Air-Cooled Screw Chiller Service Manual. Available through Daikin Applied technical support.

Frequently Asked Questions

What does Daikin EWAD fault code L1 mean?

Fault code L1 on a Daikin EWAD chiller indicates: Inverter PCB temperature sensor fault. This is a warning alarm that requires diagnostic attention.

What causes Daikin EWAD alarm code L1?

Common causes include: Inverter board temperature sensor failure; Sensor wiring damaged; Board overheating condition

How do I fix Daikin EWAD error code L1?

Follow the recommended inspection steps below. Start with the quick check, then proceed through each step. If the fault persists after all steps, contact an authorized Daikin service representative.

Disclaimer: All lookup data is for reference only. Do not use this information to replace certified professional HVAC technician judgment. Always refer to original OEM official service manual for Daikin EWAD service procedures.